@article{KleffnerBraunAntonyuk2021, author = {Christine Kleffner and Gerd Braun and Sergiy Antonyuk}, title = {High‐Pressure Reverse Osmosis for Industrial Water Recycling: Permeate‐Sided Pressure Drop as Performance‐Limiting Factor}, series = {Chemie Ingenieur Technik}, volume = {93}, number = {9}, doi = {10.1002/cite.202100021}, url = {https://nbn-resolving.org/urn:nbn:de:hbz:832-epub4-19540}, pages = {1352 -- 1358}, year = {2021}, abstract = {Abstract In the chemical industry large amounts of saline wastewater occur. Its disposal into rivers is a considerable burden to the ecosystem. To strive for a circular economy and enable a viable raw material recycling, energy‐efficient concentration processes are requisite. High‐pressure reverse osmosis meets this criterion, but its industrial application demands suitable membrane elements that withstand the exceptional operation conditions and provide sufficient performance. Hence, new requirements regarding the design of spiral‐wound elements arise. To identify those, specific performance‐limiting effects need a better understanding.}, language = {en} }